Comtech EF Data MIDAS Management Information Base User Manual
Page 84
Management Information Base
,
Rev. 1
A-68 Appendix A,
MIB Listing
SYNTAX
LONGINT
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Select the data rate from the list of
available choices, or enter any data
rate that is valid for the traffic
modem."
::= { controlChannelTableEntry 21 }
ctrlChanReferenceEbNo OBJECT-TYPE
SYNTAX
REAL
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This is the stored value at which the
received Outbound Control Channel Eb/No
will be maintained under clear sky conditions,
as measured at the LinkSync modem."
::= { controlChannelTableEntry 22 }
ctrlChanUplinkPowerControl OBJECT-TYPE
SYNTAX
BOOLEAN
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This allows the operator to enable/disable
the Uplink Power Control option.
Uplink Power Control (UPC), a standard
feature of the MIDAS system, is the method
used to establish a network-wide reference
for power. Specifically, UPC is used to
ensure that the Outbound Control Channel
carrier is downlinked from the satellite at
a constant power level. This reference
allows each of the nodes in the network
to determine and report (via regular
polling from the NMS) if, and to what
degree, downlink degradation of a node
(and its associated traffic channels)
may be occurring due to fade, whether
from rain or other non-atmospheric
conditions."
::= { controlChannelTableEntry 23 }
ctrlChanAcquisitionRange OBJECT-TYPE
SYNTAX
LONGINT
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Maximum frequency adjustment allowed
of the nodes during node acquisition.
This is the Inbound Acquisition Range in kHz
(Range: 0 to 35).
The Acquisition Range is a value (in kilohertz)
that is used to provide additional guard band
for the bursting Inbound Control Channel. This