Comtech EF Data MIDAS Management Information Base User Manual
Page 151
Management Information Base
,
Rev. 1
Appendix A,
MIB Listing
A-135
Choices include:1/2, 2/3, 3/4, 5/6, 7/8,
etc."
::= { completedCallRecTableEntry 102 }
ccallUpLinkParamsADataRate OBJECT-TYPE
SYNTAX
LONGINT
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Select the data rate from the list of
available choices, or enter any data
rate that is valid for the traffic
modem."
::= { completedCallRecTableEntry 103 }
ccallUpLinkParamsAPowerLevel OBJECT-TYPE
SYNTAX
REAL
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This field allows the operator to enter
the TX power level setting of the traffic
modem. Power range limits (0 to -30 dBm) "
::= { completedCallRecTableEntry 104 }
ccallUpLinkParamsAClockMode OBJECT-TYPE
SYNTAX
TCLOCKMODE
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This allows the operator to select the clock
mode. Choices include: Terrestrial, Internal,
Satellite, and External Reference."
::= { completedCallRecTableEntry 105 }
ccallUpLinkParamsAPreset OBJECT-TYPE
SYNTAX
TPRESET
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This allows the operator to select the
preset option for the traffic modem.
Choices depend on the modem type, but
generally include: No, A, B, C, D. For
modems with no presets, this is always
set to No. Choosing a preset overrides
the Modulation, FEC Rate, and Data Rate
settings."
::= { completedCallRecTableEntry 106 }
ccallUpLinkParamsAReedSolomon OBJECT-TYPE
SYNTAX
BOOLEAN
ACCESS read-only
STATUS mandatory
DESCRIPTION
"To select Enable/Disable Reed-Solomon."
::= { completedCallRecTableEntry 107 }