Comtech EF Data MIDAS Management Information Base User Manual
Page 34
Management Information Base
,
Rev. 1
A-18 Appendix A,
MIB Listing
afcsetupTimeBetweenNodes OBJECT-TYPE
SYNTAX
WORD
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Minutes between alignment when multiple node
alignments are performed in day "
::= { sysAFCSetup 6 }
afcsetupNodeAlignAlarmThreshold OBJECT-TYPE
SYNTAX
THALFLONGWORD
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A node offset of greater than this number of Hertz
will cause an event to be logged "
::= { sysAFCSetup 7 }
afcsetupNodeAcquisitionTimeout OBJECT-TYPE
SYNTAX
WORD
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Timeout in seconds for initial node acquisition
(typical value is 30)"
::= { sysAFCSetup 8 }
sysPowerSetup OBJECT IDENTIFIER ::= { systemSetup 5 }
powersetupUplinkMargin OBJECT-TYPE
SYNTAX
REAL
ACCESS read-write
STATUS mandatory
DESCRIPTION
"For remote circuits under power management,
additional power (in dB) added to a circuit
when uplink conditions are unknown "
::= { sysPowerSetup 1 }
powersetupDownlinkMargin OBJECT-TYPE
SYNTAX
REAL
ACCESS read-write
STATUS mandatory
DESCRIPTION
"For remote circuits under power management,
additional power (in dB) added to a circuit
when downlink conditions are unknown "
::= { sysPowerSetup 2 }
powersetupAverageNumber OBJECT-TYPE
SYNTAX
WORD
ACCESS read-write
STATUS mandatory
DESCRIPTION
"For remote circuit under power management,
maximum number of Eb/No readings to average
together to determine link conditions"