beautypg.com

Comtech EF Data MIDAS Management Information Base User Manual

Page 57

background image

Management Information Base

,

Rev. 1

Appendix A,

MIB Listing

A-41

nodeRetryCounts40
THALFLONGWORD
}

nodeNodeID OBJECT-TYPE
SYNTAX

TNODEID

ACCESS read-write
STATUS mandatory
DESCRIPTION

"This allows the operator to type the node

ID

number."

::= { nodeTableEntry 1 }


nodeName OBJECT-TYPE
SYNTAX

OCTETSTRING30

ACCESS read-write
STATUS mandatory
DESCRIPTION

"This allows the operator to type the name of

the

node."

::= { nodeTableEntry 2 }


nodeEnabled OBJECT-TYPE
SYNTAX

BOOLEAN

ACCESS read-write
STATUS mandatory
DESCRIPTION

"To bring node active A node is created in the

disabled state, and does not become active

until it is enabled. Once enabled, the node

will be polled and brought online. On an

enabled (active) node, channels can set up

and respond to calls.

Enabled Node and Channel can't be disabled if

there is an active call related to them

Can't enable/disable a nodet when the

controller mode is not normal"

::= { nodeTableEntry 3 }


nodeStatus OBJECT-TYPE
SYNTAX

TNODEENABLESTATE

ACCESS read-only
STATUS mandatory
DESCRIPTION

"The status of node"

::= { nodeTableEntry 4 }


-- Make sure the modem type is correct for
internal and external such as
-- SNM1010 can't be an external node. For
data/internal, there are IDC-150D,
-- SNM1010. For data/external, there are 100, 150,
300, 6000, 6000, 9000, 2200,
-- 2020, 300L. For ISNN/internal, there are IDC-
150, SNM-1020. For
-- ISDN/external. There are IDC-150, 300, 2200.
For video/internal, there are