A-97

::= { directoryTableEntry 1 }


dirDirectoryNumber OBJECT-TYPE
SYNTAX

OCTETSTRING30

ACCESS read-write
STATUS mandatory
DESCRIPTION

"This is the Directory Number"

::= { directoryTableEntry 2 }


dirDirectoryType OBJECT-TYPE
SYNTAX

TCHANNELTYPE

ACCESS read-write
STATUS mandatory
DESCRIPTION

"Bearer Type (channel type) for the Directory

Number, either Data, ISDN, or Video."

::= { directoryTableEntry 3 }


dirDescription OBJECT-TYPE
SYNTAX

OCTETSTRING30

ACCESS read-write
STATUS mandatory
DESCRIPTION

"This is a text description for the Directory

Number."

::= { directoryTableEntry 4 }


dirMaxBandwidth OBJECT-TYPE
SYNTAX

LONGINT

ACCESS read-write
STATUS mandatory
DESCRIPTION

"Select the maximum bandwidth value (ISDN only).

The destination must be a Node-Channel.

For Hunt Groups, the maximum bandwidth is

determined automatically, according to the

selected Hunt Group number. The maximum

bandwidth is limited to the maximum

bandwidth setting on the Node-Channel. If the

Node-Channel maximum bandwidth is set

to Default, then it is determined from the System

Setup, ISDN Settings, Grade of Service."

::= { directoryTableEntry 5 }


dirHuntGroupID OBJECT-TYPE
SYNTAX

OCTETSTRING30

ACCESS read-write
STATUS mandatory

::= { directoryTableEntry 6 }


dirNodeID OBJECT-TYPE
SYNTAX

TNODEID

ACCESS read-write
STATUS mandatory

::= { directoryTableEntry 7 }