Comtech EF Data MIDAS Management Information Base User Manual
Page 85

Management Information Base
,
Rev. 1
Appendix A,
MIB Listing
A-69
value is used to complement the operation of
Automatic Frequency Control (AFC), and allows
nodes a wider sweep range when performing
transmit acquisition by the nodes in systems
where satellite frequency translation error
may exceed the limited demodulator sweep range
of the SNM-1001 Control Channel modem.
This value is stored in the database, and used by
the bandwidth manager task to assign frequencies
for traffic channels, with respect to the additional
guard band. This value is also sent to the nodes when
they are commanded to become enabled, where it is
stored and then used by the Node Control modem to
limit the transmit sweep range when performing
transmit acquisition. This allows the node to have
a controlled sweep range to compensate for excessive
frequency offsets in the network, while preventing
interference with adjacent carriers."
::= { controlChannelTableEntry 24 }
ctrlChanDeltaPowerLimit OBJECT-TYPE
SYNTAX
REAL
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Not
used"
::= { controlChannelTableEntry 25 }
ctrlChanTransponderName OBJECT-TYPE
SYNTAX
OCTETSTRING30
ACCESS read-write
STATUS mandatory
DESCRIPTION
"the transponder which the control channel run."
::= { controlChannelTableEntry 26 }
ctrlChanEnabled OBJECT-TYPE
SYNTAX
BOOLEAN
ACCESS read-write
STATUS mandatory
DESCRIPTION
"2: To bring control channel online"
::= { controlChannelTableEntry 27 }
ctrlChanCCStatus OBJECT-TYPE
SYNTAX
TCONTROLCHANNELSTATUS
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Not
used"
::= { controlChannelTableEntry 28 }
ctrlChanOperationTag OBJECT-TYPE
SYNTAX
TOPERATION
ACCESS read-write
STATUS mandatory
DESCRIPTION