Comtech EF Data MIDAS Management Information Base User Manual
Page 30
Management Information Base
,
Rev. 1
A-14 Appendix A,
MIB Listing
::= { sysParameters 6 }
sysParaLockTime OBJECT-TYPE
SYNTAX
WORD
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This the amount of time, in seconds, that a node
will wait after a circuit is successfully established
before checking the traffic modems for loss of
carrier. In this manner, it is only after this stabilization
period that the node would send a terminate message
back to the NMS in the event that the circuit failed due to
carrier loss. Reducing this amount of time would cause
a terminate message sooner if the circuit fails due
to loss of carrier."
::= { sysParameters 7 }
sysParaMaxNode OBJECT-TYPE
SYNTAX
WORD
ACCESS read-write
STATUS mandatory
DESCRIPTION
"the max number of nodes which Midas can
manage."
::= { sysParameters 8 }
sysISDNSetup OBJECT IDENTIFIER ::= { systemSetup 2 }
isdnsetupSNMPowerLevel OBJECT-TYPE
SYNTAX
REAL
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Nominal power level for ISDN circuit"
::= { sysISDNSetup 1 }
isdnsetupSNTCPowerLevel OBJECT-TYPE
SYNTAX
REAL
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Nominal ISDN power for C band SNT terminal "
::= { sysISDNSetup 2 }
isdnsetupSNTKuPowerLevel OBJECT-TYPE
SYNTAX
REAL
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Nominal ISDN power for Ku band SNT terminal "
::= { sysISDNSetup 3 }
isdnsetupModulation OBJECT-TYPE
SYNTAX
TMODULATION
ACCESS read-write
STATUS mandatory