Management Information Base

,

Rev. 1

A-14 Appendix A,

MIB Listing

::= { sysParameters 6 }


sysParaLockTime OBJECT-TYPE
SYNTAX

WORD

ACCESS read-write
STATUS mandatory
DESCRIPTION

"This the amount of time, in seconds, that a node

will wait after a circuit is successfully established

before checking the traffic modems for loss of

carrier. In this manner, it is only after this stabilization

period that the node would send a terminate message

back to the NMS in the event that the circuit failed due to

carrier loss. Reducing this amount of time would cause

a terminate message sooner if the circuit fails due

to loss of carrier."

::= { sysParameters 7 }


sysParaMaxNode OBJECT-TYPE
SYNTAX

WORD

ACCESS read-write
STATUS mandatory
DESCRIPTION

"the max number of nodes which Midas can

manage."

::= { sysParameters 8 }


sysISDNSetup OBJECT IDENTIFIER ::= { systemSetup 2 }

isdnsetupSNMPowerLevel OBJECT-TYPE
SYNTAX

REAL

ACCESS read-write
STATUS mandatory
DESCRIPTION

"Nominal power level for ISDN circuit"

::= { sysISDNSetup 1 }


isdnsetupSNTCPowerLevel OBJECT-TYPE
SYNTAX

REAL

ACCESS read-write
STATUS mandatory
DESCRIPTION

"Nominal ISDN power for C band SNT terminal "

::= { sysISDNSetup 2 }


isdnsetupSNTKuPowerLevel OBJECT-TYPE
SYNTAX

REAL

ACCESS read-write
STATUS mandatory
DESCRIPTION

"Nominal ISDN power for Ku band SNT terminal "

::= { sysISDNSetup 3 }


isdnsetupModulation OBJECT-TYPE
SYNTAX

TMODULATION

ACCESS read-write
STATUS mandatory