Comtech EF Data MIDAS Management Information Base User Manual
Page 160

Management Information Base
,
Rev. 1
A-144 Appendix A,
MIB Listing
SYNTAX
BOOLEAN
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable/Disable to display debugging information
such as in/out SNMP messages"
::= { debugAgent 6 }
maintenance OBJECT IDENTIFIER ::= { midas 7 }
-- Use the Service Message option to send a
message or a command from the
-- Operator Workstation to the remote node
terminal, and directly to the node.
-- The message can be up to 28 characters in
length. All commands issued to a
-- remote node must begin with a prefix of
"IDC>". Refer to the IDC-150 Network
-- Control Modem Operation and Maintenance
Manual for a complete listing of
-- all commands supported.
-- The purpose of this option is to allow
simple, text-based communication
-- between the remote node and the operator,
and to provide the operator
-- with remote command capability. Any commands
of up to 28 characters
-- that can be accepted from the remote node
terminal through the user
-- port can be sent as a service message. The
operator can send such
-- commands to a remote node for configuration
or call requests.
-- All service messages from the remote node to
the NMS are displayed in
-- the Event Log. Similarly, all responses for
commands originating from the
-- Operator Workstation are displayed in the
Event Log.
serviceMessage OBJECT IDENTIFIER ::= { maintenance 1 }
toNode OBJECT-TYPE
SYNTAX
WORD
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Node ID which service message is sent to"
::= { serviceMessage 1 }
toChannel OBJECT-TYPE
SYNTAX
WORD
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Not
used"
::= { serviceMessage 2 }