"This allows the operator to select the
forward error correction rate (FEC) to
be used for the channel. Choices include:
1/2, 2/3, 3/4, 5/6, 7/8, etc."
::= { circuitTableEntry 102 }
circuitUpLinkParamsADataRate OBJECT-TYPE
SYNTAX
LONGINT
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Select the data rate from the list of
available choices, or enter any data
rate that is valid for the traffic
modem."
::= { circuitTableEntry 103 }
circuitUpLinkParamsAPowerLevel OBJECT-TYPE
SYNTAX
REAL
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This field allows the operator to enter
the TX power level setting of the traffic
modem. Power range limits (0 to -30 dBm)"
::= { circuitTableEntry 104 }
circuitUpLinkParamsAClockMode OBJECT-TYPE
SYNTAX
TCLOCKMODE
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This allows the operator to select the clock
mode. Choices include: Terrestrial, Internal,
Satellite, and External Reference."
::= { circuitTableEntry 105 }
circuitUpLinkParamsAPreset OBJECT-TYPE
SYNTAX
TPRESET
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This allows the operator to select the
preset option for the traffic modem A.
Choices depend on the modem type, but
generally include: No, A, B, C, D. For
modems with no presets, this is always
set to No. Choosing a preset overrides
the Modulation, FEC Rate, and Data Rate
settings."
::= { circuitTableEntry 106 }
circuitUpLinkParamsAReedSolomon OBJECT-TYPE
SYNTAX
BOOLEAN
ACCESS read-write
STATUS obsolete
DESCRIPTION