powersetupAverageTimeLimit OBJECT-TYPE
SYNTAX
WORD
ACCESS read-write
STATUS mandatory
DESCRIPTION
"For remote circuit under power management,
maximum time to keep an Eb/No readings"
::= { sysPowerSetup 4 }
powersetupUPCTimeInterval OBJECT-TYPE
SYNTAX
WORD
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Number of seconds between EB/No readings
of the outbound control channel, taken at the
hub for uplink power control"
::= { sysPowerSetup 5 }
powersetupUPCThreshold OBJECT-TYPE
SYNTAX
REAL
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Minimum change in power level (in dB) for
adjusting output power of outbound control
channel for uplink power control "
::= { sysPowerSetup 6 }
powersetupTFCThreshold OBJECT-TYPE
SYNTAX
REAL
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Not
used"
::= { sysPowerSetup 7 }
powersetupPowerBumping OBJECT-TYPE
SYNTAX
BOOLEAN
ACCESS read-write
STATUS mandatory
DESCRIPTION
"If true, high priority circuits can bump low
priority circuits when they would otherwise
be blocked by site power limits"
::= { sysPowerSetup 8 }
sysVideoASetup OBJECT IDENTIFIER ::= { systemSetup 6 }
videoAsetupPowerLevel OBJECT-TYPE
SYNTAX
REAL
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Broadcaster video default values"