beautypg.com

Comtech EF Data MIDAS Management Information Base User Manual

Page 35

background image

Management Information Base

,

Rev. 1

Appendix A,

MIB Listing

A-19

::= { sysPowerSetup 3 }


powersetupAverageTimeLimit OBJECT-TYPE
SYNTAX

WORD

ACCESS read-write
STATUS mandatory
DESCRIPTION

"For remote circuit under power management,

maximum time to keep an Eb/No readings"

::= { sysPowerSetup 4 }


powersetupUPCTimeInterval OBJECT-TYPE
SYNTAX

WORD

ACCESS read-write
STATUS mandatory
DESCRIPTION

"Number of seconds between EB/No readings

of the outbound control channel, taken at the

hub for uplink power control"

::= { sysPowerSetup 5 }


powersetupUPCThreshold OBJECT-TYPE
SYNTAX

REAL

ACCESS read-write
STATUS mandatory
DESCRIPTION

"Minimum change in power level (in dB) for

adjusting output power of outbound control

channel for uplink power control "

::= { sysPowerSetup 6 }


powersetupTFCThreshold OBJECT-TYPE
SYNTAX

REAL

ACCESS read-write
STATUS mandatory
DESCRIPTION

"Not

used"

::= { sysPowerSetup 7 }


powersetupPowerBumping OBJECT-TYPE
SYNTAX

BOOLEAN

ACCESS read-write
STATUS mandatory
DESCRIPTION

"If true, high priority circuits can bump low

priority circuits when they would otherwise

be blocked by site power limits"

::= { sysPowerSetup 8 }


sysVideoASetup OBJECT IDENTIFIER ::= { systemSetup 6 }

videoAsetupPowerLevel OBJECT-TYPE
SYNTAX

REAL

ACCESS read-write
STATUS mandatory
DESCRIPTION

"Broadcaster video default values"