beautypg.com

Comtech EF Data MIDAS Management Information Base User Manual

Page 50

background image

Management Information Base

,

Rev. 1

A-34 Appendix A,

MIB Listing

"This field allows the operator to type the amount in

dB of the modem-to-HPA TX gain.

(Range: 0 to 60)

Net gain from modem output to base of

antenna."

::= { siteTableEntry 13 }


siteccRefEbNo OBJECT-TYPE
SYNTAX

REAL

ACCESS read-write
STATUS mandatory
DESCRIPTION

"0.0 .. 20.0 dB

This field allows the operator to type the reference

Eb/N0 (in dB) for the control channel.

(Range: 0 to 20).

Nominal received Eb/No from control

Channel

outbound."

::= { siteTableEntry 14 }


siteTrafficRefEbNo OBJECT-TYPE
SYNTAX

REAL

ACCESS read-write
STATUS mandatory
DESCRIPTION

"0.0 .. 20.0 dB

This field allows the operator to type the

reference Eb/N0 (in dB) for the traffic channel.

Nominal Eb/No expected for traffic

Channel."

::= { siteTableEntry 15 }


sitetxGainOffSet OBJECT-TYPE
SYNTAX

REAL

ACCESS read-write
STATUS mandatory
DESCRIPTION

"-10.0 .. +10.0 dB

This field allows the operator to type the offset

in dB for the TX gain. (Range: -10 to +10)

Offset value added to ModemHPATxGain.

Normally

0."

::= { siteTableEntry 16 }


siteHPAPowerRated OBJECT-TYPE
SYNTAX

REAL

ACCESS read-write
STATUS mandatory
DESCRIPTION

"0 .. 1000 W

This field allows the operator to type the rated

power level in Watts. (Range: 0 to 1000).

Rated output power of HPA."

::= { siteTableEntry 17 }


siteHPAPowerBackOff OBJECT-TYPE
SYNTAX

REAL