MIB Listing
"This field allows the operator to type the amount in
dB of the modem-to-HPA TX gain.
(Range: 0 to 60)
Net gain from modem output to base of
antenna."
::= { siteTableEntry 13 }
siteccRefEbNo OBJECT-TYPE
SYNTAX
REAL
ACCESS read-write
STATUS mandatory
DESCRIPTION
"0.0 .. 20.0 dB
This field allows the operator to type the reference
Eb/N0 (in dB) for the control channel.
(Range: 0 to 20).
Nominal received Eb/No from control
Channel
outbound."
::= { siteTableEntry 14 }
siteTrafficRefEbNo OBJECT-TYPE
SYNTAX
REAL
ACCESS read-write
STATUS mandatory
DESCRIPTION
"0.0 .. 20.0 dB
This field allows the operator to type the
reference Eb/N0 (in dB) for the traffic channel.
Nominal Eb/No expected for traffic
Channel."
::= { siteTableEntry 15 }
sitetxGainOffSet OBJECT-TYPE
SYNTAX
REAL
ACCESS read-write
STATUS mandatory
DESCRIPTION
"-10.0 .. +10.0 dB
This field allows the operator to type the offset
in dB for the TX gain. (Range: -10 to +10)
Offset value added to ModemHPATxGain.
Normally
0."
::= { siteTableEntry 16 }
siteHPAPowerRated OBJECT-TYPE
SYNTAX
REAL
ACCESS read-write
STATUS mandatory
DESCRIPTION
"0 .. 1000 W
This field allows the operator to type the rated
power level in Watts. (Range: 0 to 1000).
Rated output power of HPA."
::= { siteTableEntry 17 }
siteHPAPowerBackOff OBJECT-TYPE
SYNTAX
REAL