beautypg.com

Comtech EF Data MIDAS Management Information Base User Manual

Page 51

background image

Management Information Base

,

Rev. 1

Appendix A,

MIB Listing

A-35

ACCESS read-write
STATUS mandatory
DESCRIPTION

"0.0 .. 10.0 dB

This field allows the operator to type the backoff

amount in dB. (Range: 0 to 10).

Recommended power back off for

Multi-carrier operation of HPA."

::= { siteTableEntry 18 }


siteccBurstPower OBJECT-TYPE
SYNTAX

REAL

ACCESS read-write
STATUS mandatory
DESCRIPTION

"-30.0 .. -5.0 dBm

This field allows the operator to type the Control

Channel Burst TX power in dBm.

Modem burst power for control channel

inbound."

::= { siteTableEntry 19 }


siteNcsState OBJECT-TYPE
SYNTAX

TNCSSTATE

ACCESS read-only
STATUS mandatory
DESCRIPTION

"The status of the site."

::= { siteTableEntry 20 }


siteOperationTag OBJECT-TYPE
SYNTAX

TOPERATION

ACCESS read-write
STATUS mandatory
DESCRIPTION

"2. delete the site

Before a site is deleted, all nodes under the

site should be deleted."

::= { siteTableEntry 99 }


-- Once the operator has
established a Site, one or many Nodes
-- can be created and configured. A
Node in the MIDAS
-- system provides the traffic
channel characteristics for the
-- required services, and operates
with the NMS to support the
-- satellite communications network
circuit management and
-- local resource management.

nodes OBJECT IDENTIFIER ::= { siteConfigurations 3 }

-- Site table must be inserted before Node table
-- Channel table must be deleted before Node table
related to it is deleted