Comtech EF Data MIDAS Management Information Base User Manual
Page 51

Management Information Base
,
Rev. 1
Appendix A,
MIB Listing
A-35
ACCESS read-write
STATUS mandatory
DESCRIPTION
"0.0 .. 10.0 dB
This field allows the operator to type the backoff
amount in dB. (Range: 0 to 10).
Recommended power back off for
Multi-carrier operation of HPA."
::= { siteTableEntry 18 }
siteccBurstPower OBJECT-TYPE
SYNTAX
REAL
ACCESS read-write
STATUS mandatory
DESCRIPTION
"-30.0 .. -5.0 dBm
This field allows the operator to type the Control
Channel Burst TX power in dBm.
Modem burst power for control channel
inbound."
::= { siteTableEntry 19 }
siteNcsState OBJECT-TYPE
SYNTAX
TNCSSTATE
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The status of the site."
::= { siteTableEntry 20 }
siteOperationTag OBJECT-TYPE
SYNTAX
TOPERATION
ACCESS read-write
STATUS mandatory
DESCRIPTION
"2. delete the site
Before a site is deleted, all nodes under the
site should be deleted."
::= { siteTableEntry 99 }
-- Once the operator has
established a Site, one or many Nodes
-- can be created and configured. A
Node in the MIDAS
-- system provides the traffic
channel characteristics for the
-- required services, and operates
with the NMS to support the
-- satellite communications network
circuit management and
-- local resource management.
nodes OBJECT IDENTIFIER ::= { siteConfigurations 3 }
-- Site table must be inserted before Node table
-- Channel table must be deleted before Node table
related to it is deleted