beautypg.com

Comtech EF Data MIDAS Management Information Base User Manual

Page 117

background image

Management Information Base

,

Rev. 1

Appendix A,

MIB Listing

A-101


circuitEnabled OBJECT-TYPE
SYNTAX

TENABLEDDISABLEDSTATUSTYPE

ACCESS read-write
STATUS mandatory
DESCRIPTION

"To

enable/disable

circuit.

Can't enable/disable a circuit when the controller

mode is not normal"

::= { circuitTableEntry 9 }


circuitActivation OBJECT-TYPE
SYNTAX

TACTIVATIONTYPE

ACCESS read-write
STATUS mandatory
DESCRIPTION

"This option group allows the operator to select

the Activation type. There are three types to

choose

from:

PERMANENT this type of Predefined Connection

is typically used as a dedicated, exclusive

connection for guaranteed availability.

SCHEDULED CIRCUIT this type of Predefined

Connection is available only on an as scheduled

basis.

RTS/DTR Request to Send; this type of

Predefined Connection can only be established

from a remote site, and is typically used as an

emergency backup, for circuit restoration

purposes when terrestrial circuits fail."

::= { circuitTableEntry 10 }


circuitPriority OBJECT-TYPE
SYNTAX

WORD

ACCESS read-write
STATUS mandatory
DESCRIPTION

" A High Priority call will preempt a Normal call if

no bandwidth is available.

Reserved for future use."

::= { circuitTableEntry 11 }


circuitBlocking OBJECT-TYPE
SYNTAX

BOOLEAN

ACCESS read-write
STATUS mandatory

::= { circuitTableEntry 12 }


circuitBumping OBJECT-TYPE
SYNTAX

BOOLEAN

ACCESS read-write
STATUS mandatory

::= { circuitTableEntry 13 }


circuitAccessByDirNum OBJECT-TYPE
SYNTAX

BOOLEAN

ACCESS read-write