Comtech EF Data MIDAS Management Information Base User Manual
Page 40

Management Information Base
,
Rev. 1
A-24 Appendix A,
MIB Listing
::= { sysRedundantController 4 }
redundantCtrlSwitchover OBJECT-TYPE
SYNTAX
BOOLEAN
ACCESS read-write
STATUS mandatory
DESCRIPTION
"To switch over between online and standby
In order to perform a redundant switch operation,
the online controller must be in 'normal' state for
the mode and 'primary' for the primary status in
the
MIB"
::= { sysRedundantController 5 }
-- This branch provides the content
of the dongle key
sysKey OBJECT IDENTIFIER ::= { systemSetup 9 }
keyMaxNumberofNodesEnabled OBJECT-TYPE
SYNTAX
WORD
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Max number of operable nodes in Midas"
::= { sysKey 1 }
keyLinkSyncPowerManagement OBJECT-TYPE
SYNTAX
BOOLEAN
ACCESS read-only
STATUS mandatory
DESCRIPTION
"whether the controller includes power management."
::= { sysKey 2 }
keyRedundantController OBJECT-TYPE
SYNTAX
BOOLEAN
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Whether the controller includes redundant function. "
::= { sysKey 3 }
keyExpirationDate OBJECT-TYPE
SYNTAX
TDATE
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the expiration date when midas controller
runs."
::= { sysKey 4 }
keyStatus OBJECT-TYPE
SYNTAX
TKEYSTATUS
ACCESS read-only
STATUS mandatory
DESCRIPTION