beautypg.com

Comtech EF Data MIDAS Management Information Base User Manual

Page 40

background image

Management Information Base

,

Rev. 1

A-24 Appendix A,

MIB Listing

::= { sysRedundantController 4 }


redundantCtrlSwitchover OBJECT-TYPE
SYNTAX

BOOLEAN

ACCESS read-write
STATUS mandatory
DESCRIPTION

"To switch over between online and standby

In order to perform a redundant switch operation,

the online controller must be in 'normal' state for

the mode and 'primary' for the primary status in

the

MIB"

::= { sysRedundantController 5 }


-- This branch provides the content
of the dongle key

sysKey OBJECT IDENTIFIER ::= { systemSetup 9 }

keyMaxNumberofNodesEnabled OBJECT-TYPE
SYNTAX

WORD

ACCESS read-only
STATUS mandatory
DESCRIPTION

"Max number of operable nodes in Midas"

::= { sysKey 1 }


keyLinkSyncPowerManagement OBJECT-TYPE
SYNTAX

BOOLEAN

ACCESS read-only
STATUS mandatory
DESCRIPTION

"whether the controller includes power management."

::= { sysKey 2 }


keyRedundantController OBJECT-TYPE
SYNTAX

BOOLEAN

ACCESS read-only
STATUS mandatory
DESCRIPTION

"Whether the controller includes redundant function. "

::= { sysKey 3 }


keyExpirationDate OBJECT-TYPE
SYNTAX

TDATE

ACCESS read-only
STATUS mandatory
DESCRIPTION

"the expiration date when midas controller

runs."

::= { sysKey 4 }


keyStatus OBJECT-TYPE
SYNTAX

TKEYSTATUS

ACCESS read-only
STATUS mandatory
DESCRIPTION