23 interrupt controller assignments, Table 4-1, P5020 / p5010 external interrupt assignments – Artesyn MVME8100/MVME8110 Installation and Use (September 2014) User Manual
Page 91: Interrupt controller assignments, Functional description

Functional Description
MVME8100 / MVME8110 Installation and Use (6806800P25G)
91
4.23 Interrupt Controller Assignments
The following table shows the external interrupts connected to the P5020 / P5010:
Table 4-1 P5020 / P5010 External Interrupt Assignments
P5020 / P5010 Interrupt
Interrupt Source
Description
IRQ0
None
Reserved
IRQ1
BCM5482 INT1
BCM5482 PHY interrupt 1 from LED_P1[2] pin
IRQ2
BCM5482 INT2
BCM5482 PHY interrupt 2 from LED_P2[2] pin
IRQ3/GPIO21
QUART_IRQ0
Quart Interrupt INTA
IRQ4/GPIO22
QUART_IRQ1
Quart Interrupt INTB
IRQ5/GPIO23
QUART_IRQ2
Quart Interrupt INTC
IRQ6/GPIO24
QUART_IRQ3
Quart Interrupt INTD
IRQ7/GPIO25
CPLD_TEMP_INT_L
Board Temperature interrupt (routed through
CPLD)
IRQ8/GPIO26
CPLD_TIMER_INT_L
CPLD Internal Timers and Abort IRQ
IRQ9/GPIO27
BCM54616S INT
BCM54616S PHY interrupt from LED4 pin.
IRQ10/GPIO28
SRIO_IRQ_INT_L
80HCPS1616 SRIO IRQ_N pin (applicable to
MVME8100 only)
IRQ11/GPIO29
RTC_INT_L
RTC interrupt (routed through CPLD)
IRQ10/GPIO28 with interrupt source SRIO_IRQ_INT_L is applicable to MVME8100 only.