2 s3 switch, Table 2-6, S3 switch settings – Artesyn MVME8100/MVME8110 Installation and Use (September 2014) User Manual

Page 38: Table 2-7, Three row backplane manual slot addressing, Hardware preparation and installation

background image

Hardware Preparation and Installation

MVME8100 / MVME8110 Installation and Use (6806800P25G)

38

2.4.1.2

S3 Switch

The TSI148 VMEbus Status Register provides the VMEbus geographical address of the
MVME8100 / MVME8110. Applications not using a 5-row backplane can use these switches to
manually assign board's VMEbus geographical address. Note that this switch is wired parallel
with geographical address pins on the 5-row connector to these switches must be in the off
position when installed in a 5-row chassis in order to get the correct address from P1
connector. This switch reflects the inverted states on the geographical address signals.

Below is the switch configuration for corresponding slot address in a 21 slot chassis 3-row
backplane.

Table 2-6 S3 Switch Settings

Position

Default

Description

1

OFF

OFF - SPI FLASH Write Protect is Disabled
ON - SPI FLASH Write Protect is Enabled

2

OFF

P0 Connector Port B PCIE/SRIO Fabric Selection (Applicable to MVME8100
only)
OFF- Port B same as Port A selection and is controlled by SW2-8
ON - Port B selection is opposite of SW2-8 selection

3

OFF (1)

GAP#

4

OFF (1)

GA4#

5

OFF (1)

GA3#

6

OFF (1)

GA2#

7

OFF (1)

GA1#

8

OFF (1)

GA0#

Table 2-7 Three Row Backplane Manual Slot Addressing

S1-3

S1-4

S1-5

S1-6

S1-7 S1-8 GAP# GA(4:0)#

Slot Address

OFF

OFF

OFF

OFF

OFF

ON

1 11110

1

OFF

OFF

OFF

OFF

ON

OFF

1 11101

2

ON

OFF

OFF

OFF

ON

ON

0 11100

3

OFF

OFF

OFF

ON

OFF

OFF

1 11011

4