beautypg.com

20 power management, Functional description – Artesyn MVME8100/MVME8110 Installation and Use (September 2014) User Manual

Page 86

background image

Functional Description

MVME8100 / MVME8110 Installation and Use (6806800P25G)

86

The CPLD provides the following functions:

Power control and fault detection

Reset sequence and reset management

Status and Control registers

Miscellaneous control logics

Watchdog timer

32-bit Tick Timers

Clock generator

Switch decoder and LED controller

4.20 Power Management

The 5 volt coming from the back plane is utilized to derive all on-board voltage rails. To provide the required
voltage sequencing, each voltage rail is controlled by the CPLD through enable pin of each regulator and the
output is being monitored by CPLD through each regulator power good signal. If one voltage rail fails, the
CPLD will disable all of the regulators and the only way to restart the board is by power cycling the chassis 5
volt power.