beautypg.com

Max 10 embedded memory design consideration, Implement external conflict resolution, Customize read-during-write behavior – Altera MAX 10 Embedded Memory User Manual

Page 17: Max 10 embedded memory design consideration -1, Implement external conflict resolution -1, Customize read-during-write behavior -1

background image

MAX 10 Embedded Memory Design

Consideration

3

2015.05.04

UG-M10MEMORY

Subscribe

Send Feedback

There are several considerations that require your attention to ensure the success of your designs.

Implement External Conflict Resolution

In the true dual-port RAM mode, you can perform two write operations to the same memory location.

However, the memory blocks do not have internal conflict resolution circuitry.
To avoid unknown data being written to the address, implement external conflict resolution logic to the

memory block.

Customize Read-During-Write Behavior

Customize the read-during-write behavior of the memory blocks to suit your design requirements.

Figure 3-1: Difference Between the Two Types of Read-during-Write Operations —Same Port and

Mixed Port.

Port A
data in

Port B
data in

Port A
data out

Port B
data out

Mixed-port
data flow
Same-port
data flow

FPGA Device

Related Information

Read-During-Write

on page 2-3

©

2015 Altera Corporation. All rights reserved. ALTERA, ARRIA, CYCLONE, ENPIRION, MAX, MEGACORE, NIOS, QUARTUS and STRATIX words and logos are

trademarks of Altera Corporation and registered in the U.S. Patent and Trademark Office and in other countries. All other words and logos identified as

trademarks or service marks are the property of their respective holders as described at

www.altera.com/common/legal.html

. Altera warrants performance

of its semiconductor products to current specifications in accordance with Altera's standard warranty, but reserves the right to make changes to any

products and services at any time without notice. Altera assumes no responsibility or liability arising out of the application or use of any information,

product, or service described herein except as expressly agreed to in writing by Altera. Altera customers are advised to obtain the latest version of device

specifications before relying on any published information and before placing orders for products or services.

ISO

9001:2008

Registered

www.altera.com

101 Innovation Drive, San Jose, CA 95134