beautypg.com

12 • maintenance – Pitney Bowes DM475 User Manual

Page 177

background image

12-11

12 • Maintenance

SV62261 Rev. F

Filling the Moistener (DM400c/DM475)

1. For the DM400, check the sight window on the front to see the

liquid level. For DM475, check the indicator in the top cover.

2. Open the feeder access cover (DM400c) or the feeder/WOW

cover (DM475).

3. Remove the moistener bottle, and place it on the table top with

its cap facing up.

Check Level
Here

Feed Access
Cover

Check Level
Here

Feeder/
WOW Cover

DM400c

DM475

DM400c Moistener Bottle

DM475 Moistener Bottle

3. Unscrew the moistener bottle cap and fill the moist-

ener bottle with Pitney Bowes E-Z Seal

®

sealing solu-

tion. We rec om mend E-Z Seal

®

be cause it helps keep

your moist en er clean and im proves seal ing ef fi cien cy.

IMPORTANT:

Do not overfi ll the moistener bottle.

4. Screw back on the moistener bottle cap and place the bottle

back in its original location (upside down in machine).

5. Close the appropriate cover.

This manual is related to the following products: