Appendix f: pos data reading and instructions, Steps for pos data reading – FeiYu Tech FY-Panda2 Autopilot User Manual
Page 60

Guilin Feiyu Electronic Technology Co., Ltd.
Guilin Feiyu Electronic Technology Co., Ltd http://www.feiyu-tech.com [email protected]
Page 57
( 2 ) Airspeed Sensor calibration: Suggest that calibration in the windless flight
environment.
Take off after Airspeed Sensor initialization. Keep the aircraft level flight, observe the
current airspeed and the GPS speed try to calibrate both to uniform (Also suggest that
the airspeed less than GPS speed 5~10KM).
The calibration operation: If the current airspeed larger than the GPS speed please
reduce the airspeed parameter
——―ASP‖ in page ―Param1‖ on tool bar, otherwise
increasing the
―ASP‖ then click on the ―Set‖ button to confirm the modify. Check again, if
the current airspeed is normally to the desired value please click on "Save" button in
page ―Param1‖ on the tool bar to save the parameter.
Appendix F: POS Data Reading And Instructions
1. Steps for POS data reading
1) Establish the connection between Panda
Ⅱ autopilot and the GCS software.
2)
Select ―Menu‖ –―Read Pos Data‖, it will load the POS information read dialog box.
3)
Click the ―Read File List ‖ the file will display in sequence.
4) Select the file you want click
―Read File‖ button, then the information box will display
the content of the file.
5) Click
―Save File‖ button, the selection file will be saved to the computer. Select the
desired saving path, input the file name in the Pop-Up dialog (Please added the .txt
expanded-name).