Appendix D: Voltage Calibration Operation
( 1 ) Measure the actual voltage of the batteries, record as:V0.
( 2 ) Connect the batteries to the power manager
,the voltage display on the
GCS(BAT1) record as V1 .
Formula for voltage calibration ratio
:C=(V0 / V1) x 100
For example: Actual voltage of the batteries V0 =15.76 V ;
Voltage display on the GCS V1=15.5 V
Voltage Ratio C=(15.74/15.5) x 100=1.017*100=102
Settings of voltage calibration:
―Menu‖
——― Autopilot setting ‖—— ―Power Voltage
Calibration
‖, it will pop-up the setting dialog.
“Voltage Ratio”= “0” means that the voltage display without calibration. If the
voltage is need to be correct, please calculate the voltage ratio "C".
According to the above steps
,then enter into the dialog , click on“OK”button to
confirm the setting of this parameter (For example: 102).