After finish the voltage calibration, please click on ―Save‖ button in page ―Para1‖ to

save the setting to the autopilot, otherwise the autopilot will restore the original settings

after power off.

( 3 ) After the voltage calibration success, the voltage display on the

GCS(―BAT1‖) is

the power voltage which have been calibrated .

Voltage can be calibrate through USB cable connect to the autopilot directly or

calibrate through the data radio.

Appendix E: Airspeed Sensor Installation And Calibration

( 1 ) Airspeed Sensor suggest that install as the figure: The airspeed sensor needs to

pull ahead the front of the pneumatic opening and in the line with the direction of flight.

The tail end of the sensor cannot be blocked. The Airspeed sensor can be install on the

wing or in the front of the nose, please make sure the body of the aircraft does not affect

the air inlet.