beautypg.com

Comtrol ES7510 User Manual

Page 59

background image

RocketLinx ES7510 User Guide: 2000544 Rev. B

Port Control - 59

Configuration Using the Web Interface

Port Configuration Page

State

You can enable or disable the state of this port. Once you click
Disable, the port stops to link to the other end and stops to
forward any traffic. The default setting is Enable which means all
the ports are workable when you receive the ES7510.

Speed/Duplex

You can configure port speed and duplex mode of each port. Below
are the selections you can choose:

Fast Ethernet Ports 1~ 8 (fa1~fa8)

-

Auto Negotiation (default)

-

10M full-duplex (10 Full)

-

10M half-duplex (10 Half)

-

100M full-duplex (100 Full)

-

100M half-duplex (100 Half)

Gigabit Ethernet Port 9~ 10: (gi9~gi10)

-

Auto Negotiation (default)

-

10M full-duplex (10 Full)

-

10M half-duplex (10 Half)

-

100M full-duplex (100 Full)

-

100M half-duplex (100 Half)

-

1000M full-duplex (1000 Full)

Flow Control

Symmetric means that you need to activate the flow control
function of the remote network device in order to let the flow
control of that corresponding port on the switch to work.

Disable (default) means that you do not need to activate the flow
control function of the remote network device, as the flow control of
that corresponding port on the switch works.

Description

Click this field if you want to enter a port description.

Apply

Click Apply to apply the settings.

Note: You must Save the settings (

Page 122

), if you want to

maintain these settings if the ES7510 is powered off.

Technical Tip:

If both ends are not at the same speed, they cannot link with each other. If both ends
are not in the same duplex mode, they are connected by half-duplex mode.