Modbus tcp register table – Comtrol ES7510 User Manual
Page 193
RocketLinx ES7510 User Guide: 2000544 Rev. B
Modbus TCP Register Table - 193
ModBus TCP /IP Support
Modbus TCP Register Table
The ES7510 v1.3 firmware provided the initial release of the Modbus TCP/IP client service support for factory
automation applications. You can implement the modbus command using the command line interface in
console and Telnet modes, which allows you to modify some parameters such as, idle time, number of Modbus
masters, and the Modbus service port.
Note: The Modbus TCP client returns 0xFFFF to a Modbus master when pulling a reserved address.
05
Acknowledge
The slave has accepted the request and processing it, but a
long duration of time is required to do so.
06
Slave Device Busy
The slave is engaged in processing a long-duration program
command.
07
Negative
Acknowledge
The slave cannot perform the program function received in
the query.
08
Memory Parity Error
The slave attempted to read extended memory, but detected a
parity error in the memory.
Word Address
Data Type
Description
System Information
0x0000
16 words
Vender Name =
“Comtrol”
Word 0 Hi byte = ‘C’
Word 0 Lo byte = ‘o’
Word 1 Hi byte = ‘m’
Word 1 Lo byte = ‘t’
Word 2 Hi byte = ‘r’
Word 2 Lo byte = ‘o’
Word 2 Hi byte = ‘l’
Word 2 Lo byte = ‘\0’
(other words = 0)
0x0010
16 words
Product Name = "ES7510"
Word 0 Hi byte = ‘E’
Word 0 Lo byte = ‘S’
Word 1 Hi byte = ‘7’
Word 1 Lo byte = ‘5’
Word 2 Hi byte = ‘1’
Word 2 Lo byte = ‘0’
Word 5 Lo byte = ‘\0’
(other words = 0)
0x0020
128 words
SNMP system name (string)
0x00A0
128 words
SNMP system location (string)
Code
Name
Descriptions