Warning, Fault relay – Comtrol ES7510 User Manual
Page 109

RocketLinx ES7510 User Guide: 2000544 Rev. B
Warning - 109
Configuration Using the Web Interface
Warning
The ES7510 provides several types of warning features for you to remotely monitor the status of the attached
devices or changes in your network. The features include Fault Relay, System Log and SMTP Email Alert.
The following web pages are included in this group:
•
•
•
•
Optionally, you can use the CLI for configuration, see
Fault Relay
The ES7510 provides one alarm relay output (DO) that can support multiple fault conditions. The relay
contacts are energized (open) for normal operation and close under fault conditions. The fault conditions
include power failure, Ethernet port link faults, Ring topology changes, Ping failures, DI state changes or ping
remote IP address failure.
The Relay 1 field shows the current state of the relay. If the relay is triggered, the event type is marked with
an asterisk (*). The above image shows that a port link event occurred.
The following table describes Fault Relay conditions:
Fault Relay
Description
Port Link
Monitors port link down events for the selected ports.
Ring
Monitors ring topology changes.
Ping
If the target IP address does not reply to the ping request, the fault relay
is enabled.
Ping Reset
Pings target device and triggers the relay to emulate to emulate a power
reset on the remote device if the remote system crashes.
•
IP Address: Remote device IP address whose power wiring is
connected with relay output.
•
Reset Time (Sec): Duration that the relay contact is opened to
emulate the power switch is off. After the reset time, the relay closes
to emulate that the power switch is on.
•
Hold Time (Sec): Boot time that the remote device requires. After
the relay contact closes the ES7510 starts pinging after the hold time.