Comtrol ES7510 User Manual
Page 173

RocketLinx ES7510 User Guide: 2000544 Rev. B
Warnings (CLI) - 173
Configuration Using the Command Line Interface (CLI)
Event Selection
Event Selection
Switch(config)# warning-event
coldstart Switch cold start event
warmstart Switch warm start event
linkdown Switch link down event
linkup Switch link up event
authentication Authentication failure event
fault-relay Switch fault relay event
loop-protect Switch loop protection event
poe-powering Switch PoE powering or unpowered event
ring Switch ring event
time-sync Switch time synchronize event
Example:
Cold Start event
Switch(config)# warning-event coldstart
Set cold start event enable ok.
Example:
Link Up event
Switch(config)# warning-event linkup
[IFNAME] Interface list, ex: fa1,fa3-5, gi9-gi10
Switch(config)# warning-event linkup
Set fa5 link up event enable ok.
Display
Switch# show warning-event
Warning Event:
Cold Start: Enabled
Warm Start: Disabled
Authentication Failure: Disabled
Link Down: fa4-5
Link Up: fa4-5
Ring: Disabled
Fault Relay: Disabled
Time synchronize Failure: Disabled
PoE Powering: