Alarm Terminals

You can connect a variety of sensors to the camera by using alarm terminals.

See following table for functions of each terminal.

Name

Function

Description

ALARM IN

Alarm Input

■ Inputs External Alarm signal.

You can choose the type of input signal:

Normal Opened (NO) or Normal Closed (NC).

Connect a sensor or other devices to the

camera.

ALARM OUT

Alarm Output

■Outputs open corrector.

Max.DC 24V, 50mA.

Output holding time follows the those of

Alarm Settings/Alarm Output. (^page 73)

GND

GND

GND for a signal

ALARM IN

Alarm input terminal

ALARM OUT

Alarm output terminal

GND

■ Connecting External Alarm Devices to the Alarm Input/Output

Terminals

■ Be sure to connect cables of external alarm devices before connecting

AC adaptor cable and LAN cable to the camera.

■ When you place IK-WB11A outside, be sure to waterproof the devices and

cables just like the power cord and LAN cable by using conduit pipes

or the like.