AERCO/ProtoNode Gateway

OMM-0080_0D

AERCO International, Inc.

• 100 Oritani Dr. • Blauvelt, New York 10913 • Phone: 800-526-0288

VD2:011712
1

GF-129

Equipment

Point Name

Name

Read
Only

BACnet
Type:ID

N2 Type

N2 ID

Lon SNVT
NAME

Lon SNVT

Lon Direction

ModBus/Unit
Address

09-Ret Flow Temp

returntemp_13

AV:130

data float

130

nvoMlxRetTmp
13

inc count (9)

Output (non-polled)

41004/13

Mlx Addr 14

01-Act Mod Lev

boilerstate_14

AV:131

data float

131

nvoMlxState14

inc count (9)

Output (non-polled)

41009/14

02-Target Setpoint

effectsetpt_14

AV:132

data float

132

nvoMlxSetpt14

inc count (9)

Output (non-polled)

41019/14

03-Req Outlet Temp

setpt_14

AV:133

data float

133

nviMlxSetptRq1
4

inc count (9)

Input (non-polling)

41005/14

04-Net Direct Drive

boilercmd_14

AV:134

data float

134

nviMlxCmd14

inc count (9)

Input (non-polling)

40002/14

05-Mod Lev In

boilerload_14

AV:135

data float

135

nvoMlxLoad14

inc count (9)

Output (non-polled)

41201/14

06-Flow Sens Temp

localsuptemp_1
4

AV:136

data float

136

nvoMlxSupTmp
14

inc count (9)

Output (non-polled)

41003/14

07-Display Code

dispcode_14

AV:137

data float

137

nvoMlxDispCod
e14

inc count (9)

Output (non-polled)

30001/14

11-Error Code

errcode_14

AV:138

data float

138

nvoMlxErrCode
14

51

Output (non-polled)

40001/14

08-Unit Status

unitstat_14

AV:139

data float

139

nvoMlxStat14

inc count (9)

Output (non-polled)

30002/14

09-Ret Flow Temp

returntemp_14

AV:140

data float

140

nvoMlxRetTmp
14

inc count (9)

Output (non-polled)

41004/14

Mlx Addr 15

01-Act Mod Lev

boilerstate_15

AV:141

data float

141

nvoMlxState15

inc count (9)

Output (non-polled)

41009/15

02-Target Setpoint

effectsetpt_15

AV:142

data float

142

nvoMlxSetpt15

inc count (9)

Output (non-polled)

41019/15

03-Req Outlet Temp

setpt_15

AV:143

data float

143

nviMlxSetptRq1
5

inc count (9)

Input (non-polling)

41005/15

04-Net Direct Drive

boilercmd_15

AV:144

data float

144

nviMlxCmd15

inc count (9)

Input (non-polling)

40002/15

05-Mod Lev In

boilerload_15

AV:145

data float

145

nvoMlxLoad15

inc count (9)

Output (non-polled)

41201/15

06-Flow Sens Temp

localsuptemp_1
5

AV:146

data float

146

nvoMlxSupTmp
15

inc count (9)

Output (non-polled)

41003/15

07-Display Code

dispcode_15

AV:147

data float

147

nvoMlxDispCod
e15

inc count (9)

Output (non-polled)

30001/15

C.2.6 - Twelve C-Mores, Six ECS/SP, Four Modulex, and Two ACS/BMS II (Cont.)