Aerco/protonode gateway, Gf-129, User manual – AERCO ProtoNode Gateway Rev 1 (with internal LEDs) User Manual

Page 53

background image

Page 53 of 64

USER MANUAL

AERCO/ProtoNode Gateway

OMM-0080_0D

AERCO International, Inc.

• 100 Oritani Dr. • Blauvelt, New York 10913 • Phone: 800-526-0288

VD2:011712
1

GF-129

Equipment

Point Name

Name

Read
Only

BACnet
Type:ID

N2 Type

N2 ID

Lon SNVT
NAME

Lon SNVT

Lon Direction

ModBus/Unit
Address

Blr Addr 10

01-Fire Rate Out

boilerstate_10

AV:91

data float

91

nvoBlrState10

inc count (9)

Output (non-polled)

30009/10

02-Active Setpoint

effectsetpt_10

AV:92

data float

92

nvoEffSetpt10

inc count (9)

Output (non-polled)

30017/10

03-Net Remote Setpt

setpt_10

AV:93

data float

93

nviSetpt10

inc count (9)

Input (non-polling)

40001/10

05-Fire Rate In

boilerload_10

AV:95

data float

95

nvoBlrLoad10

inc count (9)

Output (non-polled)

30018/10

06-Outlet Temp

localsuptemp_1
0

AV:96

data float

96

nvoLocSupTmp
10

inc count (9)

Output (non-polled)

30003/10

07-Display Code

dispcode_10

AV:97

data float

97

nvoDispCode1
0

inc count (9)

Output (non-polled)

30001/10

08-Unit Status

unitstat_10

AV:98

data float

98

nvoUnitStat10

inc count (9)

Output (non-polled)

30002/10

09-Run Cycles

runcycles_10

AV:99

data float

99

nvoRunCycles1
0

51

Output (non-polled)

30012-30013/10

10-Run Hours

runhours_10

AV:100

data float

100

nvoRunHours1
0

51

Output (non-polled)

30014-30015/10

Blr Addr 11

01-Fire Rate Out

boilerstate_11

AV:101

data float

101

nvoBlrState11

inc count (9)

Output (non-polled)

30009/11

02-Active Setpoint

effectsetpt_11

AV:102

data float

102

nvoEffSetpt11

inc count (9)

Output (non-polled)

30017/11

03-Net Remote Setpt

setpt_11

AV:103

data float

103

nviSetpt11

inc count (9)

Input (non-polling)

40001/11

05-Fire Rate In

boilerload_11

AV:105

data float

105

nvoBlrLoad11

inc count (9)

Output (non-polled)

30018/11

06-Outlet Temp

localsuptemp_1
1

AV:106

data float

106

nvoLocSupTmp
11

inc count (9)

Output (non-polled)

30003/11

07-Display Code

dispcode_11

AV:107

data float

107

nvoDispCode1
1

inc count (9)

Output (non-polled)

30001/11

08-Unit Status

unitstat_11

AV:108

data float

108

nvoUnitStat11

inc count (9)

Output (non-polled)

30002/11

09-Run Cycles

runcycles_11

AV:109

data float

109

nvoRunCycles1
1

51

Output (non-polled)

30012-30013/11

10-Run Hours

runhours_11

AV:110

data float

110

nvoRunHours1
1

51

Output (non-polled)

30014-30015/11

C.2.6 - Twelve C-Mores, Six ECS/SP, Four Modulex, and Two ACS/BMS II (Cont.)