beautypg.com

KEYENCE LJ-V7000 Series User Manual

Page 58

background image

58

LJ-V7000_COM_RM_E

9.2.9.12 Profile storage data storage order and specific example

Stored profile data, measurement values and internal measurement values (*1) can be acquired
using GetStorageProfile. The acquired data has the following structure when there is 1 byte per
row.
*1 "Internal measurement values" refers to measurements taken immediately before the OUT

settings measuring mode processing. Each OUT internal measurement value is saved
individually for each piece of profile data.

The structure of 1 piece of profile storage data

* The tolerance judgment result of internal measurement values is always 0.

0

1

2

3

4 Measurement results (OUT1)

Measurement value information

BYTE

5 LJV7IF_MEASURE_DATA

Tolerance judgment result

BYTE

6

reserve

BYTE

7

reserve

BYTE

8

Measurement value

9

10

11

124 Measurement results (OUT16)

Measurement value information

BYTE

125 LJV7IF_MEASURE_DATA

Tolerance judgment result

BYTE

126

reserve

BYTE

127

reserve

BYTE

128

Measurement value

129

130

131

132 Profile data

Header

䇭LJV7IF_PROFILE_HEADER

133

154

155

156

When 800 profiles

3355

3356

Footer LJV7IF_PROFILE_FOOTER

3357

3358

3359

3360 Measurement results (OUT1)

Measurement value information

BYTE

3361 LJV7IF_MEASURE_DATA

Tolerance judgment result

BYTE

3362

reserve

BYTE

3363

reserve

BYTE

3364

Measurement value

3365

3366

3367

3480 Measurement results (OUT16)

Measurement value information

BYTE

3481 LJV7IF_MEASURE_DATA

Tolerance judgment result

BYTE

3482

reserve

BYTE

3483

reserve

BYTE

3484

Measurement value

3485

3486

3487

FLOAT

FLOAT

FLOAT

FLOAT

DWORD

Time accumulated

* Refer to "Profile data amount calculation method" for the number of profiles.
The number changes according to the settings. Unsigned 32 bit data

Measurement value
(Example: When the
measuring mode is
peak hold, the held
value is the output
measurement value)

Internal
measurement value
(Example:
Measurements for
the profile.
Measurements taken
immediately before
measuring mode
processing)