beautypg.com

KEYENCE LJ-V7000 Series User Manual

Page 55

background image

55

LJ-V7000_COM_RM_E

(ii) For configuration 2

Heads: 2
Measurement range X direction: Full
Binning: on
Wide: off
Compression (X axis): 2
Compression (time axis): On

The amount of profile data is 200
The profile data storage order is as follows. (See profile data storage order for 1)

1. Head A MAX profiles (200)
2. Head A MIN profiles (200)
3. Head B MAX profiles (200)
4. Head B MIN profiles (200)

When getting 10 profiles with LJV7IF_GetProfile, the data below is stored in pdwProfileData.

Profile 1

LJV7IF_PROFILE_HEADER

32bit×6

1. Head A MAX profiles (200)

32bit×800
(800=200×4)

2. Head A MIN profiles (200)

3. Head B MAX profiles (200)

4. Head B MIN profiles (200)

LJV7IF_PROFILE_FOOTER

32bit×1

.

.

.

Profile 10

LJV7IF_PROFILE_HEADER

32bit×6

1. Head A MAX profiles (200)

32bit×800
(800=200×4)

2. Head A MIN profiles (200)

3. Head B MAX profiles (200)

4. Head B MIN profiles (200)

LJV7IF_PROFILE_FOOTER

32bit×1