Get setting initialize setting – KEYENCE LJ-V7000 Series User Manual
Page 34

34
LJ-V7000_COM_RM_E
Get setting
Initialize setting
Format
LONG LJV7IF_GetSetting(LONG lDeviceId, BYTE byDepth,
LJV7IF_TARGET_SETTING TargetSetting, void* pData, DWORD dwDataSize);
Parameters
lDeviceId(in)
Specifies the communication device to communicate with.
byDepth(in)
Specifies the level of the setting value to get. (LJV7IF_SETTING_DEPTH)
TargetSetting(in)
Identifies the item that is the target to get.
pData(out)
Specifies the buffer to receive the setting data that was acquired.
dwDataSize(in)
The size of the buffer to receive the acquired data in BYTEs.
* For details on the parameters, see the appendix.
Return value
No individual return code
Explanation
This function gets the setting for the specified item from the controller.
Supported version
1.00
Format
LONG LJV7IF_InitializeSetting(LONG lDeviceId, BYTE byDepth, BYTE
byTarget);
Parameters
lDeviceId(in)
Specifies the communication device to communicate with.
byDepth(in)
Specifies the level to reflect the initialized setting. (LJV7IF_SETTING_DEPTH)
byTarget (in)
Specifies the setting that is the target for initialization.
(LJV7IF_INIT_SETTING_TARGET)
Return value
No individual return code
Explanation
This function initializes the setting specified as the initialization target.
For the procedure to reflect the setting on the controller, see "9.2.9.3 Write
processing for settings".
Supported version
1.00