Normal measurement function [b-0]
Displays/outputs the measured value continuously.
Timing diagram
*
When the timing input is turned ON, the display and comparator output is held.
Peak hold function [b-1]
Measures the "maximum value" during a specified period (sampling period).
For the peak hold function, the sampling period can be specified with the
combination of the trigger mode and delay time settings.
➮ For the details of the trigger mode and delay time, refer to pages 69 and 70.
➮ For the details of flicker delay, refer to pages 70 to 73.
•
The sampling period is between the UP edge of the timing input (hold-reset
input) and the UP edge of the next timing input.
•
The value measured at the instant when the timing input turns ON is displayed/
output.
Reference: To clear the measured value being held and to start the measurement
again, short-circuit the hold-reset and GND terminals.
(t)
0
ON
OFF
ON
OFF
ON
OFF
LOW OUT
GO OUT
HIGH OUT
ON
OFF
ON
OFF
Timing input
HIGH limit value
LOW limit value
Displayed value
(t)
0
ON
OFF
When the power is turned ON or the hold-reset signal is input,
the display shows " " until the first timing signal is input.
Displayed value
Timing input
Peak hold
value
Sampling period
Sampling period
Sampling period