Chapter 2 Quick Guide to Basic Mode Operation
2
16
7. Set the upper value for the tolerance limit.
For a press, set the threshold value to the amount of the rise of the bottom dead
center due to swarf.
1) Press the
key.
•
The sensor enters the tolerance limit setting mode.
•
The setting number is displayed.
Note: Press the
key for a short time. When the key is pressed for 2 seconds or
longer, the sensor enters the function setting mode and displays “Ab[d”. If you
accidentally put the sensor into the function setting mode, press the
key again
to return to the measurement state.
2) Press the
key to display the desired setting number.
•
Pressing the
key changes the setting number sequentially.
•
“x” indicates the hysteresis setting. (
➮ Refer to page 85.)
Reference: Four kinds of tolerance limit values (“0” to “3”) can be saved in the
memory. The registered setting numbers can be switched using external signals.
(
➮ Refer to page 4.)
3) Press the
key.
•
The sensor automatically enters the HIGH limit value setting mode.
•
The setting value is displayed in red and the HIGH indicator illuminates.
SET
CALL
HIGH
TIM
GO
LOW
FUNC
UTILITY
MODE
CALIB
Mode No
key
HIGH
TIM
GO
LOW
Stripper or upper die
Die set
Lower die
Upper limit value