Chapter 2 Quick Guide to Basic Mode Operation
2
19
•
The measurement mode has been factory-set to manual.
➮ For the initial setting of the functions for each measurement mode, refer to "4.1 Table of Data
Processing Functions" (page 46).
4. Press the
key to save the measurement mode setting.
The sensor returns to the measurement state.
Note: Changing the measurement mode initializes all preset values except for the
tolerance limit values.
5. Activate the machine and check the runout value during normal operation.
The value displayed in this step is the runout per cycle.
6. Set the upper value for the tolerance limit.
Calculate the upper limit value by adding the upper limit value of the required
tolerance to the value displayed during normal operation, and set the value as
the HIGH limit value.
Example
When the runout value during normal operation is "10
µm" and the tolerance is
"+30
µm", set the HIGH limit value to "0.040". When the runout value exceeds "40
µm", the comparator output is turned on.
1) Press the
key.
• The sensor enters the tolerance limit setting mode.
• The setting number is displayed.
Note: Press the
key for a short time. When the key is pressed for 2 seconds or
longer, the sensor enters the function setting mode and displays "Ab(d". If you
accidentally put the sensor into the function setting mode, press the
key again
to return to the measurement state.
2) Press the
key to display the desired setting number.
• Pressing the
key changes the setting number sequentially.
• "x" indicates the hysteresis setting (
➮ page 85).
SET
CALL
HIGH
TIM
GO
LOW
FUNC
UTILITY
MODE
CALIB
Setting No.
key