KEYENCE EX-V Series User Manual
Page 36
Chapter 2 Quick Guide to Basic Mode Operation
2
26
3. Press the
key.
•
The sensor automatically enters the HIGH limit value setting mode.
•
The setting value is displayed in red and the HIGH indicator illuminates.
Note: Setting the panel-lock function to ON allows the terminals to switch the
setting number for the tolerance limits. For details of the panel-lock function, see
"Panel-lock function [ ]" (
➮ page 43).
4. Press the
or
key to display the desired value.
•
Pressing the
key changes the flashing digit to the right.
•
Pressing the
key changes the value.
•
All digits flash when the fifth digit and sign can be changed.
5. Press the
key.
•
The HIGH limit setting value is saved. The sensor automatically enters the
LOW limit value setting mode.
•
Set the LOW limit value using the same procedure as in steps 3 and 4.
Note 1: The output is disabled during the tolerance limit value setting. When the
output is already on, however, the output is retained.
Note 2: Pressing the
key does not save the changes if [HIGH setting value -
Hysteresis] is smaller than [LOW setting value + Hysteresis]. In this case, “Err1” is
displayed. Press the
key again to cancel the error, and then specify the correct
values.