Chapter 2 Quick Guide to Basic Mode Operation
2
17
4) Press the
or
key to display the desired value.
•
Pressing the
key changes the flashing digit to the right.
•
Pressing the
key changes the value.
•
All digits flash when the fifth digit and sign can be changed.
Example
When setting the tolerance to +20
µm, specify “0020”.
5) Press the
key.
The HIGH limit setting value is saved. The sensor automatically enters the
LOW limit value setting mode.
8. Set the lower value for the tolerance limit and press the
key.
•
For a press, set the threshold value to the amount of the lowering of the
bottom dead center due to the absence of a target.
•
Set the LOW limit value using the same procedure as in steps 7 3) and 4),
and press the
key to save the value.
Note 1: The output is disabled during the tolerance limit value setting. When the
output is already on, however, the output is retained.
Note 2: Pressing the
key does not save the changes if [HIGH setting value –
Hysteresis] is smaller than [LOW setting value + Hysteresis]. In this case, “Err1” is
displayed. Press the
key again to cancel the error, and then specify the correct
values.