beautypg.com

3 minimum input time and output response time – KEYENCE EX-V Series User Manual

Page 106

background image

Chapter 6 Specifications and Dimensions

6

96

6.3

Minimum Input Time and Output Response Time

This section describes the minimum input time and the output response time of the
EX-V series.

Minimum input time

The minimum input time required for the TIMING, HOLD RESET, ZERO, OUTPUT
DISABLE and EXT1/EXT2 is as follows:

TIMING and HOLD RESET

ZERO, OUTPUT DISABLE and EXT1/EXT2

SYNC

Note: The minimum input time does not include the processing time after the signal
is received.

ON: 1.5 ms

OFF: 1.5 ms

ON OFF

ON: 15 ms

OFF: 15 ms

ON

OFF

3 ms min.

13 ms min.

2.5 ms

2.5 ms

2 ms

12.5 ms

ON

OFF

ON

OFF

ON

OFF

SYNC input

Measurement

Sensor head oscillation