Initial commissioning, 1 align transmitter and receiver, 1 prepare for alignment – Pilz PSENvip RL D P User Manual
Page 83: 2 adjustment templates, 7commissioning, 2 initial commissioning

7.2
Initial commissioning
7
Commissioning
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]
7-2
7.2
Initial commissioning
7200
Initial commissioning
7-
7.2.1
Align transmitter and receiver
Align transmitter and receiver
7-
Inbetriebnahme_Erstinbetriebnahme_Ausrichten
Please note the following when aligning the transmitter and receiver:
Once installed, the transmitter and receiver must be exactly aligned
to each other and to the tip of the upper tool. The vertical and hori-
zontal alignment is performed using adjustment templates and is dis-
played on the receiver.
The transmitter and receiver must also be aligned after changing ei-
ther the PSENvip transmitter or receiver.
7.2.1.1
Prepare for alignment
Prepare for alignment
7-
Inbetriebnahme_Erstinbetriebnahme_Ausrichtung_vorbereiten
Please note the following when preparing for alignment:
Transmitter and receiver must be installed correctly on the press
brake (see Chapter 5, "Installation") and electrically wired (see Chap-
ter 6, "Wiring").
An upper tool must be fitted to the right and left-hand edge of the
press brake.
Switch on the supply to the PSENvip.
7.2.1.2
Adjustment templates
Adjustment templates
7-
Inbetriebnahme_Erstinbetriebnahme_Justageschablonen
Two adjustment templates and the information on the display provide
support when aligning the transmitter and receiver.
Please note the different cut-outs around the cross-hair on the two ad-
justment templates. On the left-hand adjustment template in the illustra-
tion below, the cross-hair is located within a square cutout. The different
forms make it easier to secure information about the direction of move-
ment when aligning the transmitter and receiver.