beautypg.com

2 visual inspection, 7commissioning, 5 check protective equipment – Pilz PSENvip RL D P User Manual

Page 106

background image

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]

7-25

7.5

Check protective equipment

7

Commissioning

The test piece breaks the protected field. The press stroke is stopped.
The upper tool should not touch the test piece.

7.5.2

Visual inspection

Visual inspection

7-

Inbetriebnahme_Schutzeinrichtung_pruefen_Sichtpruefung

Check the following on the PSENvip transmitter and receiver

The condition of the installation and attachment

Any damage on the housing and lens

Electrical connections

Switch on the machine.

Check the messages on the display.