4.4

Description of the units

4

Function Description

The input and display field is used to

Display the active protected field mode

See chapter 8, "Operation"

Enter the overrun

See chapter 7, "Commissioning"

Menu Selection

Display the adjustment image during initial commissioning

See chapter 7, "Commissioning"

Display the adjustment image during a tool change

See chapter 7, "Commissioning"

Display of error messages and system data

See Chapter 9, "Diagnostics and Troubleshooting"

4.4.4

Communication with the safety system

Communication with the safety system

4-

Funktion_Kommunikation_Allg

Communication between the PSENvip and safety system is required if
you use tools that cannot be safeguarded in compliance with the stand-
ards (see section entitled "Tool shapes", under "Safety"). This is the
case with tool classes 2 and 3. User programs that do not support com-
munication with the PSENvip can be used if you only intend to safeguard
tools of tool class 1. This is the case with older versions of the PSENvip,
for example.

Communication between the PSENvip and the PLC safety system is
conducted via digital inputs and outputs. Some inputs and outputs on
the PSENvip have another function compared to normal mode.

Communication only occurs in the system status TEST. This status is
adopted

After power-up.

After a tool change.

After a 0/1 pulse edge at the input System-Init.

Periodically every 2 minutes.

Funktion_Kommunikation_Basis