beautypg.com

4function description, 4 description of the units – Pilz PSENvip RL D P User Manual

Page 42

background image

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]

4-15

4.4

Description of the units

4

Function Description

Acknowledgement

Input to acknowledge that a press stroke is to be performed with a
reduced protected field (front and/or rear segments blanked). The
protected field mode selected is shown on the receiver's display.
Acknowledgement = 0/1 pulse edge via pushbutton: Run selected
protected field mode

Protected field mode 1/protected field mode 2

Two safe inputs for setting the protected field mode. The CNC or
safety system provides the signal. It is only absolutely necessary to
connect the inputs to a safety system if communication is needed for
tool detection.

Protected
field mode

Bending function

1

2

0

0

Standard

1

0

Box bending

0

1

Bending with back gauge

1

1

Box bending with back gauge

INFORMATION
The inputs for protected field mode have another function during
the system status TEST. They are used for communication with
the safety system. See "Communication with a safety system" in
this section.