Enter overrun

7

Commissioning

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]

7-20

Fig. 7-19:

Enter overrun

Using the keys , select the overrun that is specified on the type
label of the press brake.

The permitted value range is 2 ... 14 mm, in 2 mm steps.

Finish the entry using the key.

The PSENvip prompts you to confirm that you accept the new over-
run:

Press the .

You can exit the menu at any time without confirming the entry by
pressing . In this case, the previous value for the overrun will
be retained.

NOTICE
Once the overrun has been entered, you will have to perform a
function test on the safety device (see section entitled "Function
test of the safety device").