4.4
Description of the units
4
Function Description
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]
4-20
System status
Funktion_Display_OSSD
Status of the OSSD
Funktion_Display_Betriebszustand
Operating status
Funktion_Display_Eingabefeld
Status
Description
SYSTEM OK
The PSENvip is performing the specified operating mode
without error, see table: "Operating status"
TEST
The PSENvip is performing calibration and internal tests.
STANDBY
The PSENvip is deactivated when the press is in setup
mode.
ERROR
An error has occurred (HOLD, STOP, FATAL). See
Chapter 9, "Diagnostics and Troubleshooting"
Status
Description
OSSD ON
The output signal switching devices OSSD1 and OSSD2
are in the ON state.
The protected field is clear.
OSSD OFF
The output signal switching devices OSSD1 and OSSD2
are in the OFF state.
The protected field is interrupted. Or the PSENvip is not in
the status: SYSTEM OK or NORMAL OPERATION
Status
Description
NORMAL OP-
ERATION
One of the protected field modes is activated, the overrun
is being monitored.
See chapter 8, "Operation"
SETUP
This is the operating mode in which you enter the overrun.
See chapter 7, "Commissioning"
TOOL CHANGE
This is the operating mode in which you track the adjust-
ment line to the tip of the tool during a tool change.
See chapter 7, "Commissioning"
ADJUSTMENT
This is the operating mode in which you set up the trans-
mitter and receiver mechanically so that they are calibrated
with each other.
See chapter 7, "Commissioning"
DIAGNOSTICS
System data and error codes are displayed in this menu.
Pilz technical support can use these to locate errors.
See Chapter 9, "Diagnostics and Troubleshooting"
MENU
On pressing the
the following
options:
- TOOL CHANGE: Adjustment during tool change
- ADJUSTMENT: Adjustment during initial commissioning
- DIAGNOSTICS: Display error codes