System beep codes – Dell PRECISION 530 User Manual
Page 193
Solving Problems
193
S y s t e m B e e p C o d e s
Code
Cause
Action
1-1-2
Microprocessor register failure
for technical assistance.
1-1-3
NVRAM read/write failure
Run the System Board Devices tests in the
1-1-4
BIOS checksum failure
Run the System Board Devices tests in the
, if possible.
1-2-1
Programmable interval timer
Run the System Board Devices tests in the
, if possible.
1-2-2
initialization failure
Run the System Board Devices tests in the
, if possible.
1-2-3
DMA page register read/write failure
Run the System Board Devices tests in the
, if possible.
1-3
Video memory failure
Run the VESA/VGA Interface tests in the
1-3-1
through
2-4-4
Memory modules not being properly identified or used See "
."
3-1-1
Slave DMA register failure
Run the System Board Devices tests in the
, if possible.
3-1-2
Master DMA register failure
Run the System Board Devices tests in the
, if possible.
3-1-3
Master interrupt mask register failure
for technical assistance.
3-1-4
Slave interrupt mask register failure
for technical assistance.
3-2-2
Interrupt vector loading failure
for technical assistance.
3-2-4
Keyboard controller failure
Otherwise,
3-3-1
NVRAM power loss
Run the System Board Devices tests in the
, if possible.
3-3-2
NVRAM configuration
Run the System Board Devices tests in the
, if possible.
3-3-3
Real-time clock (RTC) or keyboard controller not
found
Run the Keyboard and System Board Devices tests in
the
. Otherwise,
for
technical assistance.