ClearOne Converge Pro Serial User Manual
Page 66
![background image](/manuals/598131/66/background.png)
293
XOFFA – Off Attenuation Mode
This command selects/reports the off attenuation value of a Mic channel. This command can be used to replace
the OFFA command for the M group.
Command Form
: DEVICE XOFFA
Argument Type
Size
Values
Units
Channel
Channel
1
See Groups and Channels
-
Group
Group
1
3, 29 (M, V)
-
Value
Unsigned Float
2
0.00 – 60.00
(Null to query in text)
-
XPBDIAL – Dial a PB Entry by Name
This command dials a speed dial number by name. This command can be used to replace the PBDIAL command
for the R group. There is no query for this command.
Command Form
: DEVICE XPBDIAL
Argument Type
Size
Values
Units
Channel
Channel
1
See Groups and Channels
-
Group
Group
1
17, 26 (R, Z)
-
Reserved
Unsigned Short
2
0
-
Number
String
16
1 – 16 Chars
-
XREDIAL – Dial the last number again
This command redials the last number. This command can be used to replace the REDIAL command for the R
group. There is no query for this command.
Command Form
: DEVICE XREDIAL
Argument Type
Size
Values
Units
Channel
Channel
1
See Groups and Channels
-
Group
Group
1
17, 26 (R, Z)
-
Reserved
Unsigned Short
2
0
-
XRING – Ring Indication
This command indicates a ringing line. This command can be used to replace the RING command for the R
group. This command is reportable only. It cannot be queried or set.
Command Form
: DEVICE XRING
Argument Type
Size
Values
Units
Channel
Channel
1
See Groups and Channels
-
Group
Group
1
17, 26 (R, Z)
-
Value
Unsigned Short
2
0 = Ring Cycle Ended
1 = Ring Cycle Started
-
XRINGEREN – Audible Ring Enable
This command sends/reports the use of an audible ring. This command can be used to replace the RINGEREN
command for the R group.
Command Form
: DEVICE XRINGEREN
Argument Type
Size
Values
Units
Channel
Channel
1
See Groups and Channels
-
Group
Group
1
17, 26 (R, Z)
-
Value
Unsigned Short
2
0 = Off
1 = On
2 = Toggle
(Null to query in text)
-