ClearOne Converge Pro Serial User Manual
Page 59
286
TOUT – Time Out Select
This command selects/reports the inactivity time out before returning to the unit title screen on the front panel.
Command Form
: DEVICE TOUT [Value]
Argument Type
Size
Values
Units
Value
Unsigned Integer
4
0 = No Time Out
1 – 15
(Null to query in text)
Min
UID – Unit ID
This command reports the unit id. This command is read only.
Command Form
: DEVICE UID [Value]
Argument Type
Size
Values
Units
Value
Hexadecimal
4
(Sent with a Null, value returned in text)
-
VER - Version
This command reports the version of the unit. This command is read only.
Command Form
: DEVICE VER [Value]
Argument Type
Size
Values
Units
Value
String
8
Version of format MM.mm.rr
(Sent with a Null in text, value returned)
-
XAA – Auto Answer Enable/Disable
This command selects/reports the setting of auto answer. This command can be used to replace the AA
command for the R group.
Command Form
: DEVICE XAA
Argument Type
Size
Values
Units
Channel
Channel
1
See Groups and Channels
-
Group
Group
1
17, 26 (R, Z)
-
Value
Unsigned Short
2
0 = Off
1 = On
2 = Toggle
(Null to query in text)
-
XAAMB – Adaptive Ambient Mode
This command selects/reports the setting of adaptive ambient. This command can be used to replace the AAMB
command for the M group.
Command Form
: DEVICE XAAMB
Argument Type
Size
Values
Units
Channel
Channel
1
See Groups and Channels
-
Group
Group
1
3, 29 (M, V)
-
Value
Unsigned Short
2
0 = Off
1 = On
2 = Toggle
(Null to query in text)
-