beautypg.com

ClearOne Converge Pro Serial User Manual

Page 47

background image

274

PASML – PA Sound Mask Level

This command selects/reports the sound mask level on a PA channel.

Command Form

: DEVICE PASML [Amplitude]

Argument Type

Size

Values

Units

Channel

Channel

1

See Groups and Channels

-

Group

Group

1

23 (J)

-

Amplitude

Signed Short

2

-60.00 – 20.00
(Null to query in text)

dB

PASMM – PA Sound Mask Mode

This command selects/reports the sound mask mode on a PA channel.

Command Form

: DEVICE PASMM [Value]

Argument Type

Size

Values

Units

Channel

Channel

1

See Groups and Channels

-

Group

Group

1

23 (J)

-

Value

Unsigned Short

2

0 = Voice Mode
1 = Wideband Mode
(Null to query in text)

-

PASMT – PA Sound Mask Timer

This command selects/reports the timer on sound mask signal on a PA channel.

Command Form

: DEVICE PASMT [Value]

Argument Type

Size

Values

Units

Channel

Channel

1

See Groups and Channels

-

Group

Group

1

23 (J)

-

Value

Unsigned Short

2

0 – 1440 (24 hours)
(Null to query in text)

Minutes

PATO – PA Thermal Overload

This indicates if a thermal overload condition is occurring on one of the power amplifier channels. This is Read-
Only, and is automatically generated if a overload occurs.

Command Form

: DEVICE PATO [Bitmap]

Argument Type

Size Values

Units

Bitmap

Hexa-
decimal
Integer

4

-

PBDIAL – Dial a PB Entry by Argument

This command dials a speed dial number by name.

There is no query for this command.

Command Form

: DEVICE PBDIAL

Argument

Type

Size

Values

Units

Channel

Channel

1

See Groups and Channels

-

Group

Group

1

17 (R)

-

Reserved

Unsigned Integer

2

0

-

Label

String

16

1 – 16 chars

-