beautypg.com

ClearOne Converge Pro Serial User Manual

Page 19

background image

246

COMPRESS – Compressor Adjust

This command selects/reports the settings of the compressor.

Command Form

: DEVICE COMPRESS [Threshold Ratio Attack Release Gain]

Argument

Type

Size

Values

Units

Channel

Channel

1

See Groups and Channels

-

Group

Group

1

5 (P)

-

Threshold

Signed Integer

1

-60 – 20
(Null to query in text)

dB

Ratio

Unsigned Integer

1

1 – 20

Attack

Unsigned Float

2

0.00 – 100.00

Ms

Release

Unsigned Integer

2

100 – 2000

Ms

Gain

Unsigned Float

4

0.00 – 20.00

dB

COMPSEL – Compression Select

This command selects/reports the compressor activation.

Command Form

: DEVICE COMPSEL [Value]

Argument Type

Size

Values

Units

Channel

Channel

1

See Groups and Channels

-

Group

Group

1

5 (P)

-

Value

Unsigned Integer

2

0 = Off
1 = On
2 = Toggle
(Null to query in text)

-

COUNTRY – Country Selection

This command sets / reports the country for telco compliance purposes.

Command Form

: DEVICE COUNTRY [Value]

Argument Type

Size

Values

Units

Value

Unsigned Integer

4

1 = US / Canada
2 = Europe
3 = Mexico
4 = Australia
5 = South Africa
6 = Japan
7 = Brazil
8 = South Korea
9 = China
10 = Singapore
11 = Taiwan
12 = New Zealand
13 = India
14 = Hong Kong
15 = Malaysia
16 = Argentina
(Null to query in text)

-

CTRLMASTER – Control Master Mode

This command reports the mode of the unit for SNMP control.

Command Form

: DEVICE CTRLMASTER [Value]

Argument Type

Size

Values

Units

Value

Unsigned Integer

4

1 = Master
2 = Slave
(Null to query in text)

-