ClearOne Converge Pro Serial User Manual
Page 19
![background image](/manuals/598131/19/background.png)
246
COMPRESS – Compressor Adjust
This command selects/reports the settings of the compressor.
Command Form
: DEVICE COMPRESS
Argument
Type
Size
Values
Units
Channel
Channel
1
See Groups and Channels
-
Group
Group
1
5 (P)
-
Threshold
Signed Integer
1
-60 – 20
(Null to query in text)
dB
Ratio
Unsigned Integer
1
1 – 20
Attack
Unsigned Float
2
0.00 – 100.00
Ms
Release
Unsigned Integer
2
100 – 2000
Ms
Gain
Unsigned Float
4
0.00 – 20.00
dB
COMPSEL – Compression Select
This command selects/reports the compressor activation.
Command Form
: DEVICE COMPSEL
Argument Type
Size
Values
Units
Channel
Channel
1
See Groups and Channels
-
Group
Group
1
5 (P)
-
Value
Unsigned Integer
2
0 = Off
1 = On
2 = Toggle
(Null to query in text)
-
COUNTRY – Country Selection
This command sets / reports the country for telco compliance purposes.
Command Form
: DEVICE COUNTRY [Value]
Argument Type
Size
Values
Units
Value
Unsigned Integer
4
1 = US / Canada
2 = Europe
3 = Mexico
4 = Australia
5 = South Africa
6 = Japan
7 = Brazil
8 = South Korea
9 = China
10 = Singapore
11 = Taiwan
12 = New Zealand
13 = India
14 = Hong Kong
15 = Malaysia
16 = Argentina
(Null to query in text)
-
CTRLMASTER – Control Master Mode
This command reports the mode of the unit for SNMP control.
Command Form
: DEVICE CTRLMASTER [Value]
Argument Type
Size
Values
Units
Value
Unsigned Integer
4
1 = Master
2 = Slave
(Null to query in text)
-