beautypg.com

ClearOne Converge Pro Serial User Manual

Page 35

background image

262

LOGMASK – Device Log Mask

This command sets or reports the device event log mask.

Command Form

: DEVICE LOGMASK [Value]

Argument Type

Size

Values

Units

Value

Hexadecimal

4

XXXX XXXX XXXX XXXX XXXX XXXX XXXX XXXX
|||| |||| |||| |||| |||| |||| |||| ||||> Reset
|||| |||| |||| |||| |||| |||| |||| |||> Errors
|||| |||| |||| |||| |||| |||| |||| ||> Password Access
|||| |||| |||| |||| |||| |||| |||| |> Telco On/Off
|||| |||| |||| |||| |||| |||| ||||> Dial
|||| |||| |||| |||| |||| |||| |||> Call Duration
|||| |||| |||| |||| |||| |||| ||> System Checks
|||| |||| |||| |||| |||| |||| |> Firmware Download
|||| |||| |||| |||| |||| ||||> (Reserved)
|||| |||| |||| |||| |||| |||> Default
|||| |||| |||| |||| |||| ||> (Reserved)
|||| |||| |||| |||| |||| |> (Reserved)
|||| |||| |||| |||| ||||> Safety Mute
|||| |||| |||| |||| |||> Macro Execution
|||| |||| |||| |||| ||> Preset Execution
|||| |||| |||| |||| |> Audio Clipping
|||| |||| |||| ||||-> Microphone Gains
|||| |||| |||| |||-> Processor Gains
|||| |||| |||| ||-> Fader Gains
|||| |||| |||| |-> Telco Gains
|||| |||| ||||-> Power Amp. Gains
|||| |||| |||-> Power Amp. Errors
|||| |||| ||-> Caller ID
|||| |||| |-> SIP Message Log
|-------|-> (Reserved)
(Null to query in text)

-

LVL – Level

This command reports the level of a channel. This command is read only.

Command Form

: DEVICE LVL [Value]

Argument Type

Size

Values

Units

Channel

Channel

1

See Groups and Channels

-

Group

Group

1

1, 2, 3, 5, 7, 12, 16, 17, 20, 25, 26
(I, J, O, M, P, L, F, T, R, K, Z)

-

Position

Meter Type

2

See Meter Type Definitions

-

Value

Signed Float

4

-99.99 – 99.99
(Sent with Null in text, Value returned)

dB

LVLREPORT – Level Report

This command selects/reports the status of level reporting for the specified channel.

Command Form

: DEVICE LVLREPORT [Value]

Argument Type

Size

Values

Units

Channel

Channel

1

See Groups and Channels

-

Group

Group

1

1, 2, 3, 5, 7, 12, 16, 17, K, Z
(I, J, O, M, P, L, F, T, R, K, Z)

-

Position

Meter Type

2

See Meter Type Definitions

-

Value

Unsigned Integer

4

0 = Off (Delete from list being reported)
1 = On (Add to list being reported)
2 = Toggle
(Null to query in text)

-